What Is a Cooling Flush and Why Do Owners Do It?
A cooling flush is a burst of water run through the group before you make a shot. It clears the overheated water that has been sitting in the heat exchanger tube. Some makers call it a requirement. Others don't mention it. Your own manual decides.
Why the water needs clearing
The tube sits inside a boiler that's hotter than the shot should be. When the machine idles, the water in the tube keeps getting heat. One source says the heat exchanger can turn that water into steam if the machine is idle for more than 5 or 10 minutes.1
A shot made with that water would be too hot. So you replace it first.
One maker's manual states the reason briefly. The boiler heats brew water only indirectly. So the manual says owners must flush for several seconds before pulling a shot.2
What you'd see and hear
The Vibiemme manual says to flush without the portafilter. It says to wait until the sputtering of the steam ends and water without steam comes from the group.3 One retailer's method differs on the portafilter, so do whatever your own manual says. The retailer says hissing, sputtering and uneven flow mean the brew water is flash boiling, meaning it's turning to steam as it leaves.4
The end of the sputtering is not the stop signal. The Vibiemme manual says that once the steam stops you count an amount of time, then turn the brew cycle off.3 The retailer says the water is still about 206 to 207°F (about 97°C) when the flow turns uniform. Each extra second of flushing drops it by about 1°F. Its 5 to 6 extra seconds are the retailer's way to reach about 201°F on its own example machine.4 Use the length in your own manual.
So the cue is the water itself, but only the start of the count. Rough, spitting flow means it's still too hot. Smooth flow means the water is still too hot, and the extra flushing time comes next.
The numbers differ
Makers and retailers don't agree on one set of figures, and they shouldn't have to. Machines differ. One retailer says as much: all machines are a little different.4
| Source | What it says |
|---|---|
| A maker's manual for an E61 group machine | Flush if the machine hasn't brewed for more than about three to five minutes, then wait about fifteen to forty-five seconds.3 |
| A retailer's tech tip | After the flow smooths out, each extra second of flushing drops brew water by about 1°F. Then wait 30 to 45 seconds.4 |
| An enthusiast article | If the machine has been idle, 4 to 8 ounces of water may need to go through.1 |
The retailer also says the right length depends on how long the machine has been idle, so a shot pulled within 10 minutes needs a much shorter flush.4
Why the wait afterwards
After a flush, new cold water sits in the tube and has to warm back up. The retailer allows 30 to 45 seconds for the new water in the heat exchanger to recover to brew temperature.4 The Vibiemme manual describes its own short wait of about fifteen to forty-five seconds after the flush, for the brew boiler temperature to settle.3 It describes the flush itself as pulling excess heat from the brew boiler and group. That's time you can use for grinding and loading the portafilter.
Don't copy someone else's count
A flush length from a forum, a video or this page isn't a setting for your machine. If your manual gives a length, use it. If it says nothing about flushing, ask the maker before building a routine around another machine's numbers.
Keep your hands clear of the group while hot water is running, and don't open the case to look for the cause of any odd behaviour. That's for the maker or a qualified technician.
To see why the water heats up in the first place, read about boiler and brew temperatures.
Notes and sources
- Single Boiler vs. Heat Exchanger, CoffeeGeek
- Profitec JUMP: User Manual, Clive Coffee Help Center
- Cooling flush (Vibiemme Domobar Junior manual, page 10), Vibiemme, via ManualsDir
- Temperature Stability On A Heat Exchanger Espresso Machine, Whole Latte Love